Basic Info.
Reference Standard
ASTM D93
Power Supply
AC 220 V, 50Hz
Heating Rate
(1~12 Degrees Celsius/Min
Product Description
Model: SLH -261
Application
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products in the temperature range from 40 degrees Celsius to 360 degrees Celsius.
I. Main technical features
1. This instrument is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously and stepless adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
II. Main technical specification and parameters
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)degrees Celsius/min;Controllable and adjustable.
4. Stirring rate:
(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
5. Standard oil cup:
(1) Inner diameter: 50.7mm~50.8mm.
(2) Depth: 55.7mm~56.0mm
(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
(4) Capacity of testing oil:about 70ml
6. Igniting device:
(1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer, correspond with GB/T261-2008 and ASTM E1.
(1)Scale( -5~11)degrees Celsius division 0.5 degrees Celsius
(2)Scale(20~150) degrees Celsius, division 1degrees Celsius
(3)Scale )90~370) degrees Celsius,division 2 degrees Celsius
8. Ambient temperature:≤ 35 degrees Celsius
9. Relative humidity:≤ 85%
10.Total power consumption:≤ 650W
Manual Type Pensky-Martens Closed Cup Flash Point Tester (SLH-261)
Address:
Building 151, No. 288 Langting Road, Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Instruments & Meters
Company Introduction:
Understanding our customers, we care about the future of our business. Up to today, with reasonable price and good quality, all our products sell well in the international marketing. We want to ensure that you get our good service, only high quality and speedy delivery. We sincerely want to supply you with high quality products and perfect service based on our efficient management and professional work teams. Because professional, so trust!